8K 雷竞技Ray

雷竞技raybet官网切换台

多功能机箱

现场直播

系统集成

关闭
  • 12G-SDI 雷竞技Ray
  • 4K/HD雷竞技Ray
  • 矩阵

  • 12G-SDI 雷竞技Ray
  • 8K/4K雷竞技Ray
  • 画面分割器

  • IP雷竞技Ray
  • 12G-SDI 雷竞技Ray
  • 4K雷竞技Ray
  • HD雷竞技Ray
  • 多功能处理器

  • 帧同步器
  • 转换器
  • 色彩校正器
  • 测试信号发生器/TC发生器/VANC调制解调器
  • 倒换器
  • 延迟器
  • 雷竞技raybet官网/音频分配器
  • 多功能机箱

  • USF系列
  • UFM系列
  • 图像处理

  • 稳定器
  • 闪光/闪烁处理器
  • 4K-HD局部提取
  • 音频处理

  • 多通道/分配器
  • 音频转换器
  • 现场直播

  • 实时回放系统
  • 自动追踪系统
  • 文件管理

  • 编码/解码器
  • 雷竞技raybet官网上载(Ingest)
  • 雷竞技raybet官网服务器
  • 存档/备份
  • 图形处理系统

  • 字幕机
  • 图形处理
  • 键控器
  • 虚拟系统
  • 雷竞技raybet官网书写器
  • 高速摄像机

  • 4K 雷竞技Ray
  • HD雷竞技Ray
  • 系统集成

  • 控制软件
  • 关闭

    P Changeover Switch

    IPS-6200

    Clean Switching Over IP
    Increasing IP circuit reliability


    Standalone ASI/TS over IP changeover in a 1U enclosure. Monitors TS-level IP signals in redundant input and instantly switches ports if errors occur, enabling seamless output without disruptions. IP-based changeover for monitoring redundant TSoIP signals from multicast TS-level encoder transmissions and seamlessly switching ports if errors occur. To prevent transmission path error, this changeover further increases the reliability of duplex transmission.


    特征

    Seamless switching between outputs of the same encoder

    When installed at the far end of a network link, the IPS-6200 seamlessly switches between redundant encoder TSoIP input used in multicast transmissions or the like. This supports completely seamless switching without video or audio disruption.


    Auto and manual switching

    When a signal error occurs, the IPS-6200 automatically switches to the other line. Manual switching and auto/manual assignment of each line are also possible. For example, the following assignment can be selected: Automatic switching  the current line to the reserve line, and manual switching  the reserve line to the current line.

    Delay adjustment function

    The delay difference between different lines is absorbed quickly and both phase inputs are automatically aligned to achieve seamless switching that does not disrupt the output. The delay adjustment range is up to 10 seconds.

    TS-level monitoring

    TS-level error monitoring, already proven reliable in switching, is used for IP signals. Error monitoring goes beyond TR 101 290 guidelines to check for packet loss, null-only, and other critical errors affecting signal quality. Error detection can also be enabled or disabled based on the type of signal. Set the PID error detection threshold as desired, in 1 ms increments. Up to sets of multi-program signals are supported.

    GUI-based remote control and monitoring

    Ethernet interfaces enable a wide range of remote monitoring and control to suit many usage scenarios. The dedicated GUI can be used to make settings and graphically display error monitoring contents via Ethernet. An event log viewer, automatic CSV file generation, and other functions are also provided to facilitate signal management requiring historical condition data. SNMP-based control, configuration, and monitoring is also supported.

    ASI and IP input both supported

    Choose ASI or IP for each signal supplied. Enables mixed input, using IN 1 on the IP side and IN 2 on the ASI side, for example. Ideal for redundant ASI/satellite operation.